Custom Assembled Electromagnetic Rf Shielding Room

As environmental electromagnetic pollution rises, RF noise increasingly interferes with sensitive and accurate measurements. 
Electromagnetic shielded rooms offer maximum shielding attenuation, creating a controlled electromagnetic environment for conducting highly sensitive tests without distortion. Additionally, RF shielded rooms are ideal for protecting meeting rooms and computer data centers in compliance with Tempest requirements.
PV:0
CONTACT US

                                         Custom Assembled Electromagnetic RF Shielding Room  

 

Spectification

Magnetic Field 9KHz≥70dB 150KHz≥80dB
Electric Field 200KHz~50MHz≥95dB (95~120dB)
Plane Wave 50MHz~1GHz≥95dB (95~120dB)
Microwave 1GHz~10GHz≥95dB (95~120dB)
Rome Size  Customize

 

Feature

 

  • Shielding Layer:

    • The shielding layer is made of 2.0mm thick galvanized steel plates, precision processed and assembled.
    • These steel plates provide good shielding effects, preventing electromagnetic wave leakage and interference.
  • Doors:

    • The doors use labor-saving shielded doors to achieve a more aesthetic effect.
    • Labor-saving shielded doors reduce the resistance of opening and closing while maintaining the shielding effect.
  • Windows:

    • The windows use shielded glass that allows natural light and can be easily opened.
    • This glass provides natural lighting while maintaining the shielding effect.
  • Ventilation Waveguide Windows:

    • Honeycomb-type ventilation waveguide windows, with dimensions of 300x300mm.
    • These waveguide windows can be connected to central air conditioning or fresh air systems and can be customized in various non-standard sizes according to the specifications of the shielded room.
  • High-Performance Low-Leakage Power Filters:

    • Capable of handling power lines of various specifications, including 220V/380V and 50Hz, for use by equipment inside the shielded room.
  • Indoor Electricals:

    • The room is equipped with a distribution box, embedded fluorescent lighting blocks (for use in the testing room, the specific quantity determined based on the required illumination), cable routing, control switches, and sockets (wall sockets, floor sockets, or socket boxes, quantity determined by user needs).
  • Interior Decoration:

    • The ceiling, walls, and floor will be decorated according to user requirements.
  • Others:

    • Air conditioning can be installed inside the shielded room based on user requirements, and signal processing will be carried out.
    • Additionally, all cables entering and exiting the machine room (such as telephone, fire alarm, monitoring, optical fiber, and various data lines) need to be shielded.
 

 

 

 

Product Details